- Data blocking in siemens. Rating: (420) Hi. The CPU type being used determines the maximum size of data blocks. Apr 6, 2020 · 1- Ngôn ngữ lập trình: LAD, FBD, STL, SCL hay graph, mình thì hay dùng LAD và SCL, S7 1200 và S7 1500 có hỗ trợ như sau: Khi Add các Block để lập trình là lúc bạn chọn lun loại ngôn ngữ coding Apr 30, 2022 · As we want to read data from a datablock, open the datablock taskpane by clicking “Data Block Value” in the ribbon. thank Jun 24, 2021 · Hello Siemens_MI; Let me see if I understand your question correctly. Last visit: 3/26/2024. PLC-Type: S7-400; IP-address: 192. Using this sof Feb 15, 2021 · DB and DI represents shared and instance data block respectively. The GET and PUT instructions are used to read or write data from another remote S7 PLC. Then you need to just copy all the DB's and UDT's from the old backup to the new and say replace all if you are sure that no changes were made to the structure of the DB or UDT Apr 15, 2021 · Hello I have a s7-1200 and i want to move a data block that has an array[0-101] of words to a data block that has an array[0-50] of real. Last visit: 2/7/2024. : 11 (we want to read from datablock 11 in our example) 2. See full list on instrumentationblog. BOOL or WORD ) can be saved in arbitrary order. Jun 27, 2009 · Joined: 1/4/2008. The S7 data block (DB 1) is 65535 bytes long. 1. Using the system data type "HSC_Period" The tag of system data type "HSC_Period" is defined in the data block "DataExample1". Posts: 12282. I use address [MC1]DB824,X106. Nov 3, 2015 · Joined: 3/25/2008. At the "dataBuffer" parameter you specify the data area for storing the data that is sent to the Modbus TCP server. Rating: (0) Hi All, I would like to know if it is possible to READ and WRITE Data Block variables from the HMI. Say, Word register address 2,0 will be named Shaft_Speed and will be used as an INT; say DWord register 16. In the code I would like to move one int value within the data block to another int value in the data block, but the move instruction does not support variables within a data block. Rating: (0) I want to move a bit (just a bit) to a data block. 2001 Seite 1/12 DP_WIN13_e. Rating: (88) Hi, I have a S7-300 CPU on a rack where I will add a CP343-1 Lean module. Click the right mouse button on [DB1] and then click [Generate source from blocks]. An instance is assigned to every call of a function block and serves as a data memory. You can define the structure of global data blocks as required. in. Understanding the different types of data blocks and their applications can significantly enhance the efficiency and reliability of your automation projects. DBW22 Decirte que puedes cambiar el número del DB antes de crearlo, por defecto en la ventana de Agregar nuevo bloque, TIA Portal te asignará de forma automática un número que no esté en uso, pero puedes seleccionar el modo Manual para asignarle el número que tu quieras. HiWhen I create a global DB in TIAv12 I can not select 300/400 compatiable. SIPROTEC 7SJ66 is featuring the flexible protection functions. Rating: (0) hello, I am new to the plc programming. Figure 8: Tools -> Add-ins -> Data Block Editor. 2 and 3. The I/O is distributed everywhere else from there. 168. 6, UDT can be used as data type. An alternative is to use the Data Block Editor as described in the next section. ” Here, you will find all the blocks available to create. Rating: (2410) In s7-1200/1500, you can configure DBs as optimized, which is very different from S7-300/400 because you can no longer access the precise memory location in the DB using the DB# and an offset value, like DB1. Access times to information on a DB is not described in the link given. Whilst you are in the SCL block, go to Basic Instructions on the right of the screen, then Move Operations, (depending on your TIA version you might need to go in to Read/Write Memory), then find POKE_BLK near the bottom of the list, hover over it for a few seconds and a link to the Help Dec 7, 2016 · Joined: 6/24/2013. In Siemens Sinumerik system, there are preconfigured data blocks which are configured to exchange Mar 25, 2019 · Data block (DB – khối dữ liệu): ta có thể bao gồm các DB trong chưorng trình người dùng. You need not enter all the parameters with the address. 1 Under [Program blocks] create “Data_block_1 [DB1]” as shown in the following figure. DBW10. May 8, 2015 · Is there a maximum cap for the number of data blocks that I can create in S7-1500 family? Is that restricted by licensing? I am using TIA Portal v13. To create a new block, right-click somewhere in the workspace, then go to “Insert New Object. Suggestion; To thank ; Quote; Answer; This contribution was helpful to . Static variables are stored in the instance data block. now i am working in scl. Posts: 1917. PLC data types (UDT) can also be used as a template for creating global data blocks. Ví dụ: Như hình bên dưới, địa chỉ Data block 1 (DB1) chỉ hiển thị ở dạng Tags, không có địa chỉ tuyệt đối dạng DB1. Inside, you create registers where your data will be written and accessed. Global data blocks store data that can be usedby all other blocks (see Figure 1). This data block or these data blocks are intended for connection and Nov 22, 2011 · Posts: 2. so how can i reset the variables. but what happen if we do not create Data Block in program? please help me, this confused me Jun 8, 2020 · Hello everyone!Welcome back for winCC and Simatic Manager tutorialIn the previous video you already created the DB(data block) for connect from SIMATIC MANAG Aug 29, 2011 · Joined: 10/7/2005. The special zinc pressurized housing guarantees you the ideal protection, even in challenging environmental conditions and temperatures from -40° to +60°C. DBX0. s _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ simatic 4 days ago · Siemens Industry Catalog - Low-Voltage controls and distribution - Circuit Protection Devices - Molded Case Circuit Breakers (MCCB) - Sentron Molded Case Circuit Breakers - External MCCB Accessories - Handle Blocking Devices Apr 4, 2012 · DearExpert and All PeopleI had a stupid Question. 6 programming software for Siemens s7-300 series. etc. Posts: 10533. Last visit: 8/29/2024. instead of moving data in the data block move pointer and overwrite oldest element of the DB: The frame size is the total time (T) to acquire one block of data. The "CTRL" parameter requires a tag of system data type "HSC_Period". I am obviously new to Siemens. 40 (as configured in the Step 7 hardware configuration) Rack: 0 ; Slot: 3; DBNo. Posts: 240. m = the start adres of your destination block, BYTE 20 states the length in bytes SFC20 = the standard blockmove instruction which is included in the standard library. Index Overview Pg 3 Selection and ordering data Pg 4 Technical data Pg 5 Characteristic curves Pg 7 Accessories Pg 10 Accessories placement Pg 11 Mar 26, 2021 · Nous allons apprendre les Data Block (DB) et la fonction MOVE dans un automate Siemens S7 dans ce tuto sur la programmation des automates Siemens S7 en langa We will create A Function Block and a Data Block for this example. Sep 24, 2022 · DB is data block i. FB1 PutGet The instructions PUT and GET are called in the FB1 "PutGet” to transfer data via the configured S7 connection. Hi friends,In this video i have explained about the Function Block (DB) in simatic manager 5. Good luck, Tielenaar Jul 13, 2019 · The following instructions are used in some uncommon configurations for saving the actual values of a data block as initial values. And it's all good. Rating: (0) Hi, Is there somebody who can explain what is "Data block derived from UDT"? I know that to create a DB in Step 7 v5. Please see attached picture of tag attributes that also shows S7-1200PLC type. DBXy. Last visit: 6/19/2024. Rating: (2681) Hello sixthomas; There are ressources you can find in the forum and on the web, discussing this issue and providing solutions to export and inport DBs to csv file. You will get to know theFunction Block Diagram (FBD) programming language and use it to program a function block (FB1) and an organization block (OB1). Data blocks thus contain variable data that is used by the user program. Oct 24, 2012 · Joined: 4/9/2010. it could be process or axis etc. Jan 10, 2019 · Joined: 2/5/2013. i know in this block data are stored. 1 thankful Users HBCM_ Jul 13, 2021 · Posts: 6. Posts: 25. An S7 connection must be configured for reading and writing. There are two types of data blocks. Global DBs, where all OBs, FBs and FCs read all saved data or can even write in the DB and local instance DBs, which are assigned a particular FB. In this tutorial, we will be looking at the different types of function block instances that can be used in PLC programming using Siemens TIA Portal. Tags of a global data block: You can define retentivity either for individual or for all tags of a global data block depending on the settings for access. com Jan 13, 2023 · In this video, I'm going to show you how to use the DATA BLOCK feature in Siemens Plc. I am using TIA V15. Only the associated function block should access instance data blocks. 2-7: Structure of the system data type "HSC_Period" "ElapsedTime" specifies the time in nanoseconds between the last counting events Jan 13, 2020 · What is the difference between an instance data block and a global data block and how does a CALL call influence the DB register? Hope this helps. It would be nice if somebody can help me with a sample code. 1 SIMATIC’s Technology Objects 1. Last visit: 8/17/2024. Mar 4, 2021 · Hi, I have a similar doubt. The first thing to notice is the arguments of the block,, which are the interface inputs and output we defined earlier. As an S7 client, the S7 CPU actively establishes the S7 connection. In the DBs, different data types (e. Already checked that it is a non-optimized blocked and it is accesible through OPC. 4 - Siemens SIMATIC Manager STEP7 PLC Programming | Calling Function Block 1 (FB1) Once done, a Function Block call will appear in the network. The problem is that i want to transfer the data block with the array of word from the second word and after. Have a look again in the TIA-manual: Basic principles for programming of data blocks. Ayman Elotaify. Rating: (2) Hello to all . User can access this information to user network also. Dữ liệu được lưu trữ vẫn duy trì khi sự thực thi của một khối mã có liên quan dần kết thúc. Aug 16, 2012 · dear all,would you please explain me the difference between using of "structure" and "UDT" in Data block. Sep 20, 2012 · Hi, when I try to compile my program, I get this message. simply block which contain data e. May 7, 2021 · Joined: 2/21/2021. Rating: (22) Create a new FC. 2 In EasyBuilder click [New PLC…], select Siemens S7-1500 (Ethernet) PLC type, and Oct 7, 2022 · Pointers do not “contain” data, they point to it. In DB some data are in structure. But I can go to properties after I created it and unselect optimized which will make the offsets column appear. 65535] of Word Entspricht dem Los DB (Data Block) pueden ser: Globales; De instancia; El acceso a los DB globales está pensado para que puedan ser usados desde cualquier parte del programa (desde un OB, FC o FB). data source and “Microsoft Excel” as data destination. (do I need to set the memory card somewere in TIA Portal?)The data block have abo Oct 24, 2017 · Joined: 7/7/2010. I think values of the variables are stored in instance data block. You also have the option of using PLC data types (UDT) as a template for creating global data blocks. Last visit: 8/23/2024. Rating: (2404) You could create a cyclic OB that is called once every so often, a minute, or whatever, and inside the OB have it count up until enough time has elapsed and then trigger a data copy/write. I would like to retain values when the power is switched off. be/Mpwa4AVvxVoVideo tutorial about how to work with properties of data blo The first thing you will notice is that both data blocks are exactly the same, that is because as we said the default setting when creating a data block is that it will be optimized, so we need to change the setting of DB2 to make it a standard block, to see if something will change. Suggestion; To thank ; Quote The call of a function block is referred to as aninstance. Sorry about my English language. Rating: (820) Hello, is that original Siemens product or 3-rd party library from GitHub? answer is simple, you need read documentation. The standard block access uses Big-Endian while optimized access uses Little-Endian. Preface Statement List (STL) for S7-300 and S7 -400 Programming 4 Reference Manual, 04/2017, A5E41492943-AA Further Support If you have any technical questions, please get in touch with your Siemens representative or SIPROTEC 7SJ66 is a multifunctional protection, control and monitoring device. Sep 26, 2016 · Joined: 8/27/2006. It would be great if anyone can suggest a good practice to limit the number of data blocks. In the case of the FB/FC as main origin, the I/O can be linked to that code block once. My version is V13 sp1. The above image shows the Function Block(FB) for the control valve operation. Apr 25, 2020 · Learn how to create Siemens PLC DB Offset Address, which can be used in data assigning to HMI/SCADA. But i don't know can i see. Posts: 3018. The downside is you can't use absolute address for direct access, only symbolic. hope this helps Block Symbolic name Description OB1 Main The FB1 "PutGet" including the associated instance data block DB1 "InstPutGet" is called cyclically in OB1. Rating: (1054) Hello alifaez let me start by stating that you can use an FB's STAT variable as a DB pointer. The data that is written to the holding register of the Modbus TCP server is stored in the data block DB3 "HoldingRegisterWrite". Posts: 1617. In the TIA project I've just added one DB with non-optimized access (don't know if it does any difference but I need this option because this DB is used for data exchange with another PLC) and a small piece of code where I rewrite some values into 2 variables from this new DB. Jul 29, 2020 · Joined: 4/28/2015. Posts: 225. Posts: 113. Posts: 15111. Để lưu trữ dữ liệu cho các khối mã. z = the start adres of your souce block, BYTE 20 states the length in bytes MWzz = a free MW for diagnostic DBoo. Last visit: 8/6/2024. DBXp. DBW 54 Trang 23 Tháng 4 năm2020 Ban Công nghiệpSố- Siemens ViệtNam USS_DRV instruction (USS Drive Control Function) Xửlý Data Block cho khốilệnhUSS_DRV Đặttên Data Block (DB) 1 2 OK = xác nhận Khi khởi tạo instruction “USS_DRV”, STEP 7 sẽ tự động khởi tạo giúp ngườidùng Data Block phù hợptươngứng. 1. Last visit: 4/8/2024. This CPU has many data blocks that contain production data. Nov 27, 2018 · used by the user program. Knust: E-Mail: michael. Fill in the right parameters. Global data blocks can be structured according to your preferences. The data block editor is another add-in (Tools -> Add-ins from main Testlab menu) that is included in the Desktop: no additional tokens are necessary. My background is in a lot of other PLC's but i'm now adding to the list, Siemens. Figure 4: Frame size (T) equals block size (N) divided by sample frequency (Fs) For example, with a block size of 2000 data points and a sampling rate of 1000 samples per second, the total time to Apr 6, 2011 · DBxx. I want to know what the concept and reason also philosophy of using data blocks in projects. Table 2-3 Variablenname Datentyp Hinweis holdingRegister Array [0 . 6, 12/2018 2 G 8 d Legal information Use of application examples Programming FB1 in Function Block Diagram Generating Instance Data Blocks and Changing Actual Values Programming a Block Call in Ladder Logic Programming a Block Call in Statement List Programming a Block Call in Function Block Diagram 37 39 43 46 50 52 55 57 In Chapters 3 to 5, you create a simple program. The data block can be expanded for each additional connection or you can create a new data block. It stores the actual parameters and the static data of the function block. In Siemens PLC terms an FC/FB or even OB stands at the head of the function unit. They are non- binding and make no claim to completeness or functionality regarding configuration and When generating data blocks, you can designate PLC data types as a type. Sep 20, 2013 · Siemens Step 7 Data Block export with all dependencies. Mar 11, 2016 · create new block like in Picture n. Jan 5, 2011 · chapter 12-Parameter Assignment for Data Blocks You may know these basic material about data blocks but the easiest way is to find the whole address is to get the starting point of the variable. En caso de excepciones se requiere el permiso por escrito de Siemens A&D SCE (Mr. If you're Jan 5, 2011 · I found pdf called Programming with step 7, and i learned how to enter data into data block. g. This way, the data is ready for the processor, that doesn't need to resort it. Oct 22, 2019 · Posts: 1. However, we won’t cover the actual programming, which will be covered in the SIMATIC Manager programming tutorial. The GET instruction reads data from the desired data area of the second PLC and assigns them to the data area of your choice in the first PLC. It boils to design choice. I create an instance DB10 and open it in STL with shared notation rather than instance: OPN DB10. How can i see address in Data Blockof PLC S7-1200 whenusing TIA Portal. In other words, I need to display on my HMI for instance temperature or pressure values stored in a DB, and also would like to enter a value for a specific varialble in the DB that in turn will be used in a PID loop. However, Temp data is stored in the local data stack which is lost after the execution of FB. Jun 22, 2023 · Thank you all. Global data blocks store data that can be used by all other blocks. 4. Posts: 703. Please help me more understand. I cretaed a data block and a few int values within the data block and ticked the box to retain the values. The maximum size of data blocks a free service by Siemens AG and/or a subsidiary of Siemens AG (“Siemens”). DBW 54[/code]loads the variable analog_valueand transfers it indataword 54(Byte 54 and 55) in the data block 1 or like this [code]OPN DB 1 L PIW 72 TDBW 22[/code]selects/opens DB 1, loads the periphery input word 72 and transfers it into data word 22 (of the actual open DB) And to read from DB just in the other direction: [code]LDB1. blocks (OBs),functions (FCs), function blocks (FBs) and data blocks (DBs). But, I can not edit the offsets. hope this helps, regards, FCK WAR! Be nice! Suggestion; To thank ; Quote; Answer Sep 25, 2012 · Posts: 15. The frame size is the block size divided by sample frequency as shown in Figure 4. This is shown in Figure 8. 5. However, Simatic s7 open data block regardless of it is shared or instance! why is it so? if there is no difference between syntax why it has declared two different notations for DBs? Aug 3, 2023 · Joined: 11/5/2012. One instance of the PLC data type is required in a data block for each connection to a communication partner; in it you define the connection parameters and the Modbus parameters. I must say i did have a bit of a chuckle when i saw the words, "basic" and "trivial" :). Now i want to use this data for some calculations I will work with FBD. ? Siemens no hace ningún tipo de garantía con respecto a su contenido. Data Block Editor. PLC data types can be used for the following: • As data types for variables in the variable declaration of code modules or in data modules. Global data blocks contain data available for use by all other blocks. The function block instance-specific data might be stored in its instance data block or the calling block's instance data block. 1 Motivation TOs of S7-1500(T) Entry ID: 109743134, V1. When using a Pointer to move data into a function block, changing the data in the function block will immediately update the reference data outside of the function block. The structure of a PLC data type consists of several elements of different data types. It uses less memory space. Regard Aug 25, 2016 · Hi fantasy198910, You can do 1 thing that first have the backup of the software that you have and is the most updated . i wanted to reset the variables i used in the function block. Last visit: 8/30/2024. This procedure can either be conducted directly within an STL source or by saving the values with Excel. Feb 4, 2021 · Data blocks (DB) are used for storing variables of different data types, For single/multi instance memory of the Standard block call. Figure 4. counter "HSC1". Creating a PLC data type for a lubricating plant depot, for example. You can create several data blocks based on this type, all of which have the same data structure. The maximum size of data blocks varies depending on the CPU. The tags declared in the function block determine the structure of the instance data block. There are no symbolic names nor structuring of the data block according to tags. 1 Motivation In order to be able to facilitate the use of technological functions that can be used Jun 7, 2010 · Say you create a Data Block for motor control data, and give it number 12. Rating: (0) Hey, I was wondering if there is a good way to transfer the data from a group of tags to a data block. Use of single instances and multi May 12, 2019 · Subscribe to this channel for more Videos and Tutorials 😊See also : https://youtu. With Step 7 manager easy to see. Posts: 719. Rating: (63) Hello, address offset is defined automatically by optimized DBs, if you need to be able to control the offset of your variables you will need to remove the "Optimized" attibute of the DB, after doing this the address offset will be displayed in its respective column in the DB. Jan 7, 2013 · Joined: 10/10/2005. FB will generate an instance data block with each call. Hello All, Is there a way in Step 7 5. I tried to access the standard controller tags and no problem but when I try to go to the DB it always give me a “Bad” connection. Rating: (0) Hello. It describe rather how the PLCs now use less space in the memory. co. Preface Function Block Diagram (FBD) for S7-300 and S7-400 Programming Reference Manual, 05/2010, A5E02790131-01 5 Online Help The manual is complemented by an online help which is integrated in the software. Posts: 287. 02. . May 19, 2024 · Data blocks are a fundamental component of Siemens PLC programming, offering robust solutions for data management and program execution. Jul 23, 2014 · My dear friend, Thank you. choose SCL as the block language, then program as shown above. 0, 05/2017 5 G 7 d 1 SIMATIC’s Technology Objects 1. knust@hvr. Does it make sense to use a data block wrapper? Thanks in advance! Jack. Last visit: 8/10/2024. I tried to put limits in PLC. Uncheck Optimized Block Access like n. TDB1. Posts: 15059. It however does not answer the question. Select Data Block and select Global DB, like n. 2. Oct 11, 2011 · Joined: 7/7/2010. www. let me ask clear : what the role of this block during program running? we know tags are categorized in tag table and we can check tags there. Rating: (33) Hi and thanks for the reply. These data blocks can be customized by changing the actual values for the appropriate task. DB1 InstPutGet Instance data block of FB1 "PutGet". En cambio, los DB de instancia están asociados a los Bloques de función FB y almacenan los valores de las variables estáticas usadas en estos FB. For programming guidance there are many manuals, Documents, Example Projects and videos are available in the SIOS portal Legal information Programming Guideline for S7-1200/1500 Entry ID: 81318674, V1. The function of data block is to transfer information/signals from NC to PLC or to HMI etc. Say you create a Data Block for motor control data, and give it number 12. DBD18 Ex2: Data block 1, data type WORD, starting address22 = DB1. Aug 20, 2011 · Posts: 4. Same thing for the PUT instruction but for writing data instead. Rating: (96) If you want the online values, you could copy the DB from online to the offline or in editor press the button for open online block (normally the third icon), after it loads press the Save, it will save the values to the offline block. Programming FB1 in Function Block Diagram Generating Instance Data Blocks and Changing Actual Values Programming a Block Call in Ladder Logic Programming a Block Call in Statement List Programming a Block Call in Function Block Diagram 5-1 5-3 5-7 5-10 5-14 5-16 5-19 5-21 STEP 7 Getting Started C79000-P7076-C48-01 v Jul 29, 2020 · Joined: 4/28/2015. Rating: (136) Hello, the block_fb identifies a specific block to be used by the STL program in the block called. Open your Data Block and write all needed things - Name of structure and Type, in your case Array of Bytes, like n. You can define the structure of global data blocks anyway you please. e. You'll learn how to design and create your own data blocks, and use them in your programs. Ex1: Data block 1, data type real, starting address18 = DB1. What is the maximum allowed size of data block?I have S7-12006ES7 214-1AG31-0XB0 with 75KB memory with 2MB MC inside. After creating, click right mouse to your DB and click properties. Rating: (5) Thanks, for answering, please note that I'm looking for DB, I cannot access this data from PLC tags menu, I can access them from Program Blocks > name [DBnumber] SIMATIC ET 200eco PN offers you a particularly rugged I/O solution in IP 65/67 and IP69K. Last visit: 8/19/2024. DOC PROFIBUS-Diagnostic package for SIMATIC S7 and WinCC A package is available for Profibus diagnosis that consists of the following components: S7 diagnostic block FB125 and FB126 for the analysis and supply of the diagnostic information of a PROFIBUS DP system. I would like to have a complete cross reference like step 7 Nov 9, 2021 · The counter idea to the design idea is to design in function units. [divider] SIEMENS 20. Jan 27, 2022 · Hello, I got a 1500 Siemens PLC accesible through Ignition but I can’t acces DB824. El préstamo o copia de este documento, incluyendo el uso e informe de su contenido, sólo se permite dentro de los centros de formación. siemens. Sep 18, 2013 · Retentivity settings can be defined only in the assigned instance data block if optimized block access has not been activated for the FB. Currently I am using the MOVE function to individually move one tag at a time to the data block. 5 SIMATIC Manager to export a data block so that it can be imported into provides the S7 data block DB1 for reading and writing, thereby becoming an S7 server. In addition, you will be introduced tolibrary-compatible function und function block programming. The F1 help was not helpful to me which is why I reached out to the forum. Sep 30, 2016 · The optimized block access rearranges the data inside the block. 3. Siemens FI 01 · 2021 5/3 Positioners SIPART PS2 Technical description 5 Overview SIPART PS2 electropneumatic positioner in polycarbonate enclosure with aluminum gauge block (optional) SIPART PS2 electropneumatic positioner in aluminum enclosure SIPART PS2 electropneumatic positioner in stainless steel enclosure with stainless steel gauge block Joined: 9/27/2006. Last visit: 9/4/2024. I'm new in tia portal. Feb 4, 2021 · A DB is a Data-Block a defined memory area. if it is correct then how can i reset the values. PLC data types are user-defined data structures that can be used several times in the program. Figure 2-2 shows a schematic diagram of the process sequence and the interfaces used in the WinCC/IndustrialDataBridge. I have a PLC running on a machine that I hardly don't want to stop. You can define its content and structure, and you are able to read and write from/to it. what would be the difference if those data would be in an UDT and call it from that DB. This means that a reference to data is created and TIA works with the original data that the pointer refers to. In this video, we're going to show you a quick introduction to Data Blocks in Siemens TIA Portal and the benefit of using Data Blocks when collecting groups of data in the PLC. de). Last visit: 8/26/2024. 0 will be named Winding_Temp and will be used as a REAl (floating-point) value. I cannot use "MOVE" since the minimum it could move is BYTE. This did help greatly. Posts: 487. gwic hjhmtyl nlmkex nvgrux okfhgs uwmkt myfwnehu mcok wemxeed bqns